BGQJD - MAGNAFLUX FLUID

Product Identification

Product ID:MAGNAFLUX FLUID
MSDS Date:01/01/1987
FSC:6850
NIIN:01-196-5472
MSDS Number: BGQJD

Responsible Party
CONTINENTAL CHEMICAL CORP/TERRE HAUTE, IN 47808

Emergency Phone: (812) 235-8035

Cage: 23894

Contractor
CONTINENTAL CHEM CORP
TERRE HAUTE, IN US

Cage: 23894

Ingredients

ALIPHATIC PETROLEUM NAPHTHA

Fraction By Weight: 100%

ACGIH TLV: 15 PPM

Hazards

Effects of Overexposure:IRRITANT TO RESP TRACT, SKIN & EYES. HARMFUL OR
FATAL IF SWALLOWED.

First Aid

First Aid:SKIN/EYES: FLUSH WITH WATER FOR 15 MINUTES & GET MEDICAL
ATTENTION. INHALATION: REMOVE TO FRESH AIR, RESTORE BREATHING IF
NEEDED. INGESTION: CALL PHYSICIAN. DON'T INDUCE VOMITING. _

Fire Fighting

Flash Point:208F (TCC)
Lower Limits:0.9%
Extinguishing Media:CO2, FOAM
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. USE FOG
NOZZLES, IF USED.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. CLOSE
CONTAINERS MAY EXPLODE IF EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:ISOLATE FROM OXIDIZERS, HEAT, & OPEN FLAME.
MOP UP & DISPOSE OF IAW EPA & LOCAL DIREIVES.

Handling

Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE AMTS IN
STRUCTURES MADE FOR CLASS III A LIQUIDS. AVOID FREE FALOF LIQUID.
GROUND CONTAINERS WHEN POURING.
Other Precautions:DON'T FLAME OUT, BRAXE OR WELD. EMPTY CONTAINERS
HAZARDOUS.

Exposure Controls

Ventilation:LOCAL EXHAUST TO KEEP VAPOR <10 PPM.
Protective Gloves:IMPERVIOUS
Eye Protection:GOGGLES
Other Protective Equipment:NONE
Supplemental Safety and Health
MSDS DATE: 11/85.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:407-608F
Vapor Pres:0.2
Vapor Density:6.0
Spec Gravity:0.802
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, WATER-WHITE; MILD, NON-RESIDUAL.
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
ISOLATE FROM STRONG OXIDIZERS SUCH AS PERMANGANATE.
Stability Condition to Avoid:ISOLATE FROM HEAT, & OPEN FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE FROM BURNING.

Disposal

Waste Disposal Methods:RECYCLE OR INCINERATE OBSERVING LOCAL, STATE,
AND FEDERAL HEALTH, SAFETY AND POLLUTION LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.